- •Series10
- •Series10
- •PRECAUTIONS FOR SAFE OPERATION
- •General
- •PRECAUTIONS
- •HOW TO READ THIS MANUAL
- •SET FUNCTIONS
- •BASIC OPERATION
- •USING THE BATTERY
- •FOCUSSING AND TARGET SIGHTING
- •POWER ON
- •ANGLE MEASUREMENT
- •DISTANCE MEASUREMENT
- •Distance measurement and Outputting the Data
- •COORDINATE MEASUREMENT
- •RESECTION MEASUREMENT
- •SETTING-OUT MEASUREMENT
- •SETTING-OUT LINE
- •POINT PROJECTION
- •OFFSET MEASUREMENT
- •MISSING LINE MEASUREMENT
- •Measuring the Distance between 2 or more Points
- •SURFACE AREA CALCULATION
- •SELECTING / DELETING A JOB
- •REGISTERING/DELETING DATA
- •OUTPUTTING JOB DATA
- •CHANGING THE SETTINGS
- •Settings in Config Mode (items set, options, and input range)
- •WARNING AND ERROR MESSAGES
- •CHECKS AND ADJUSTMENTS
- •STANDARD EQUIPMENT AND OPTIONAL ACCESSORIES
- •Tubular compass (CP7)
- •SPECIFICATIONS
- •REGULATIONS
- •EXPLANATION
21.SELECTING / DELETING A JOB
21.1Selecting a JOB
Select the current JOB and Coordinate Search JOB.
•A total of 10 JOBs have been prepared, and JOB1 was selected when your SET was shipped from the factory.
•The names of the JOBs have been preset as JOB1 to JOB10; you can change them to any names you wish.
•Scale factor can be set for each JOB. Only scale factor of the current JOB can be edited.
Current JOB
Measurement results, instrument station data, known points data, notes and coordinate data are recorded in the current JOB.
Registering known point data: “22.1 Registering/Deleting Known Point Data”.
Coordinate Search JOB
The registered coordinate data in the JOB selected here can be read into coordinate measurement, resection measurement, setting-out measurement, etc.
Scale correction
SET calculates horizontal distance and coordinates of a point using measured slope distance. If scale factor has been set, scale correction is carried out during calculation.
Corrected horizontal distance (s) = Horizontal distance (S) ×
Scale factor (S.F.)
•When scale factor is set to “1.00000000”, the horizontal distance is not corrected.
PROCEDURE JOB selection and scale factor setting
1.Select “JOB” in Memory Mode.
2.Select “JOB selection”.
JOB selection screen is displayed.
JOB selection : JOB1
S.F.=1.00000000 Coord search JOB :JOB
92
21. SELECTING / DELETING A JOB
3.Press .
•JOB can also be selected by pressing { }/{ }.
•The numbers to the right represent the number of data items in each JOB.
“*” means that the JOB has not been output to an external device yet.
4.Align the cursor with the desired JOB as the current JOB and press
{ }.
The JOB is determined.
5.Press and then press
.
Enter the scale factor for the current JOB.
6.Press .
JOB selection screen is restored.
7.Align the cursor with “Coord search
JOB” and press .
<Coord search JOB> is displayed.
8.Align the cursor with the desired JOB as the coordinate search JOB and press { }.
The JOB is determined and <JOB> is restored.
JOB selection |
46 |
||
|
JOB01 |
||
*ATUGI |
254 |
||
|
JOB03 |
0 |
|
|
JOB04 |
0 |
|
|
JOB05 |
0 |
|
|
|
JOB 1
S.F.=1.00000000
•The list of JOB names is contained on up to 2 pages.
•Scale factor input range: 0.50000000 to 2.00000000 (*1.00000000)
“*”: Factory setting
93
21. SELECTING / DELETING A JOB
PROCEDURE Inputting a JOB name
1.Select “JOB” in Memory mode.
2.Select in advance the JOB whose name to be changed.
“PROCEDURE JOB selection and scale factor setting”
3.Select “JOB name edit” in <JOB>, Input the new JOB name and press
{ }.
<JOB> is restored.
JOB name edit
A
JOB03
Maximum size of JOB name: 12 (alphanumeric)
21.2Deleting a JOB
It is possible to clear the data within a designated JOB. After the data has been cleared, the JOB name returns to the name allocated when the SET was shipped.
A JOB that has not been output to an auxiliary device (displayed with ) cannot be deleted.
PROCEDURE
1.Select "JOB" in Memory Mode.
2.Select "JOB deletion."
The JOB names are displayed in a table.
•The numbers to the right represent the number of data items in each JOB.
3.Align the cursor with the desired JOB and press { }.
JOB deletion |
46 |
|
|
JOB01 |
|
|
ATUGI |
254 |
* |
JOB03 |
0 |
|
JOB04 |
0 |
|
JOB05 |
0 |
94
|
|
21. SELECTING / DELETING A JOB |
4. Press |
. The data within the |
|
JOB that is selected is deleted and |
JOB01 |
|
<JOB deletion> is restored. |
||
|
|
deletion |
Confirm?
95