- •Preface
- •Imaging Microscopic Features
- •Measuring the Crystal Structure
- •References
- •Contents
- •1.4 Simulating the Effects of Elastic Scattering: Monte Carlo Calculations
- •What Are the Main Features of the Beam Electron Interaction Volume?
- •How Does the Interaction Volume Change with Composition?
- •How Does the Interaction Volume Change with Incident Beam Energy?
- •How Does the Interaction Volume Change with Specimen Tilt?
- •1.5 A Range Equation To Estimate the Size of the Interaction Volume
- •References
- •2: Backscattered Electrons
- •2.1 Origin
- •2.2.1 BSE Response to Specimen Composition (η vs. Atomic Number, Z)
- •SEM Image Contrast with BSE: “Atomic Number Contrast”
- •SEM Image Contrast: “BSE Topographic Contrast—Number Effects”
- •2.2.3 Angular Distribution of Backscattering
- •Beam Incident at an Acute Angle to the Specimen Surface (Specimen Tilt > 0°)
- •SEM Image Contrast: “BSE Topographic Contrast—Trajectory Effects”
- •2.2.4 Spatial Distribution of Backscattering
- •Depth Distribution of Backscattering
- •Radial Distribution of Backscattered Electrons
- •2.3 Summary
- •References
- •3: Secondary Electrons
- •3.1 Origin
- •3.2 Energy Distribution
- •3.3 Escape Depth of Secondary Electrons
- •3.8 Spatial Characteristics of Secondary Electrons
- •References
- •4: X-Rays
- •4.1 Overview
- •4.2 Characteristic X-Rays
- •4.2.1 Origin
- •4.2.2 Fluorescence Yield
- •4.2.3 X-Ray Families
- •4.2.4 X-Ray Nomenclature
- •4.2.6 Characteristic X-Ray Intensity
- •Isolated Atoms
- •X-Ray Production in Thin Foils
- •X-Ray Intensity Emitted from Thick, Solid Specimens
- •4.3 X-Ray Continuum (bremsstrahlung)
- •4.3.1 X-Ray Continuum Intensity
- •4.3.3 Range of X-ray Production
- •4.4 X-Ray Absorption
- •4.5 X-Ray Fluorescence
- •References
- •5.1 Electron Beam Parameters
- •5.2 Electron Optical Parameters
- •5.2.1 Beam Energy
- •Landing Energy
- •5.2.2 Beam Diameter
- •5.2.3 Beam Current
- •5.2.4 Beam Current Density
- •5.2.5 Beam Convergence Angle, α
- •5.2.6 Beam Solid Angle
- •5.2.7 Electron Optical Brightness, β
- •Brightness Equation
- •5.2.8 Focus
- •Astigmatism
- •5.3 SEM Imaging Modes
- •5.3.1 High Depth-of-Field Mode
- •5.3.2 High-Current Mode
- •5.3.3 Resolution Mode
- •5.3.4 Low-Voltage Mode
- •5.4 Electron Detectors
- •5.4.1 Important Properties of BSE and SE for Detector Design and Operation
- •Abundance
- •Angular Distribution
- •Kinetic Energy Response
- •5.4.2 Detector Characteristics
- •Angular Measures for Electron Detectors
- •Elevation (Take-Off) Angle, ψ, and Azimuthal Angle, ζ
- •Solid Angle, Ω
- •Energy Response
- •Bandwidth
- •5.4.3 Common Types of Electron Detectors
- •Backscattered Electrons
- •Passive Detectors
- •Scintillation Detectors
- •Semiconductor BSE Detectors
- •5.4.4 Secondary Electron Detectors
- •Everhart–Thornley Detector
- •Through-the-Lens (TTL) Electron Detectors
- •TTL SE Detector
- •TTL BSE Detector
- •Measuring the DQE: BSE Semiconductor Detector
- •References
- •6: Image Formation
- •6.1 Image Construction by Scanning Action
- •6.2 Magnification
- •6.3 Making Dimensional Measurements With the SEM: How Big Is That Feature?
- •Using a Calibrated Structure in ImageJ-Fiji
- •6.4 Image Defects
- •6.4.1 Projection Distortion (Foreshortening)
- •6.4.2 Image Defocusing (Blurring)
- •6.5 Making Measurements on Surfaces With Arbitrary Topography: Stereomicroscopy
- •6.5.1 Qualitative Stereomicroscopy
- •Fixed beam, Specimen Position Altered
- •Fixed Specimen, Beam Incidence Angle Changed
- •6.5.2 Quantitative Stereomicroscopy
- •Measuring a Simple Vertical Displacement
- •References
- •7: SEM Image Interpretation
- •7.1 Information in SEM Images
- •7.2.2 Calculating Atomic Number Contrast
- •Establishing a Robust Light-Optical Analogy
- •Getting It Wrong: Breaking the Light-Optical Analogy of the Everhart–Thornley (Positive Bias) Detector
- •Deconstructing the SEM/E–T Image of Topography
- •SUM Mode (A + B)
- •DIFFERENCE Mode (A−B)
- •References
- •References
- •9: Image Defects
- •9.1 Charging
- •9.1.1 What Is Specimen Charging?
- •9.1.3 Techniques to Control Charging Artifacts (High Vacuum Instruments)
- •Observing Uncoated Specimens
- •Coating an Insulating Specimen for Charge Dissipation
- •Choosing the Coating for Imaging Morphology
- •9.2 Radiation Damage
- •9.3 Contamination
- •References
- •10: High Resolution Imaging
- •10.2 Instrumentation Considerations
- •10.4.1 SE Range Effects Produce Bright Edges (Isolated Edges)
- •10.4.4 Too Much of a Good Thing: The Bright Edge Effect Hinders Locating the True Position of an Edge for Critical Dimension Metrology
- •10.5.1 Beam Energy Strategies
- •Low Beam Energy Strategy
- •High Beam Energy Strategy
- •Making More SE1: Apply a Thin High-δ Metal Coating
- •Making Fewer BSEs, SE2, and SE3 by Eliminating Bulk Scattering From the Substrate
- •10.6 Factors That Hinder Achieving High Resolution
- •10.6.2 Pathological Specimen Behavior
- •Contamination
- •Instabilities
- •References
- •11: Low Beam Energy SEM
- •11.3 Selecting the Beam Energy to Control the Spatial Sampling of Imaging Signals
- •11.3.1 Low Beam Energy for High Lateral Resolution SEM
- •11.3.2 Low Beam Energy for High Depth Resolution SEM
- •11.3.3 Extremely Low Beam Energy Imaging
- •References
- •12.1.1 Stable Electron Source Operation
- •12.1.2 Maintaining Beam Integrity
- •12.1.4 Minimizing Contamination
- •12.3.1 Control of Specimen Charging
- •12.5 VPSEM Image Resolution
- •References
- •13: ImageJ and Fiji
- •13.1 The ImageJ Universe
- •13.2 Fiji
- •13.3 Plugins
- •13.4 Where to Learn More
- •References
- •14: SEM Imaging Checklist
- •14.1.1 Conducting or Semiconducting Specimens
- •14.1.2 Insulating Specimens
- •14.2 Electron Signals Available
- •14.2.1 Beam Electron Range
- •14.2.2 Backscattered Electrons
- •14.2.3 Secondary Electrons
- •14.3 Selecting the Electron Detector
- •14.3.2 Backscattered Electron Detectors
- •14.3.3 “Through-the-Lens” Detectors
- •14.4 Selecting the Beam Energy for SEM Imaging
- •14.4.4 High Resolution SEM Imaging
- •Strategy 1
- •Strategy 2
- •14.5 Selecting the Beam Current
- •14.5.1 High Resolution Imaging
- •14.5.2 Low Contrast Features Require High Beam Current and/or Long Frame Time to Establish Visibility
- •14.6 Image Presentation
- •14.6.1 “Live” Display Adjustments
- •14.6.2 Post-Collection Processing
- •14.7 Image Interpretation
- •14.7.1 Observer’s Point of View
- •14.7.3 Contrast Encoding
- •14.8.1 VPSEM Advantages
- •14.8.2 VPSEM Disadvantages
- •15: SEM Case Studies
- •15.1 Case Study: How High Is That Feature Relative to Another?
- •15.2 Revealing Shallow Surface Relief
- •16.1.2 Minor Artifacts: The Si-Escape Peak
- •16.1.3 Minor Artifacts: Coincidence Peaks
- •16.1.4 Minor Artifacts: Si Absorption Edge and Si Internal Fluorescence Peak
- •16.2 “Best Practices” for Electron-Excited EDS Operation
- •16.2.1 Operation of the EDS System
- •Choosing the EDS Time Constant (Resolution and Throughput)
- •Choosing the Solid Angle of the EDS
- •Selecting a Beam Current for an Acceptable Level of System Dead-Time
- •16.3.1 Detector Geometry
- •16.3.2 Process Time
- •16.3.3 Optimal Working Distance
- •16.3.4 Detector Orientation
- •16.3.5 Count Rate Linearity
- •16.3.6 Energy Calibration Linearity
- •16.3.7 Other Items
- •16.3.8 Setting Up a Quality Control Program
- •Using the QC Tools Within DTSA-II
- •Creating a QC Project
- •Linearity of Output Count Rate with Live-Time Dose
- •Resolution and Peak Position Stability with Count Rate
- •Solid Angle for Low X-ray Flux
- •Maximizing Throughput at Moderate Resolution
- •References
- •17: DTSA-II EDS Software
- •17.1 Getting Started With NIST DTSA-II
- •17.1.1 Motivation
- •17.1.2 Platform
- •17.1.3 Overview
- •17.1.4 Design
- •Simulation
- •Quantification
- •Experiment Design
- •Modeled Detectors (. Fig. 17.1)
- •Window Type (. Fig. 17.2)
- •The Optimal Working Distance (. Figs. 17.3 and 17.4)
- •Elevation Angle
- •Sample-to-Detector Distance
- •Detector Area
- •Crystal Thickness
- •Number of Channels, Energy Scale, and Zero Offset
- •Resolution at Mn Kα (Approximate)
- •Azimuthal Angle
- •Gold Layer, Aluminum Layer, Nickel Layer
- •Dead Layer
- •Zero Strobe Discriminator (. Figs. 17.7 and 17.8)
- •Material Editor Dialog (. Figs. 17.9, 17.10, 17.11, 17.12, 17.13, and 17.14)
- •17.2.1 Introduction
- •17.2.2 Monte Carlo Simulation
- •17.2.4 Optional Tables
- •References
- •18: Qualitative Elemental Analysis by Energy Dispersive X-Ray Spectrometry
- •18.1 Quality Assurance Issues for Qualitative Analysis: EDS Calibration
- •18.2 Principles of Qualitative EDS Analysis
- •Exciting Characteristic X-Rays
- •Fluorescence Yield
- •X-ray Absorption
- •Si Escape Peak
- •Coincidence Peaks
- •18.3 Performing Manual Qualitative Analysis
- •Beam Energy
- •Choosing the EDS Resolution (Detector Time Constant)
- •Obtaining Adequate Counts
- •18.4.1 Employ the Available Software Tools
- •18.4.3 Lower Photon Energy Region
- •18.4.5 Checking Your Work
- •18.5 A Worked Example of Manual Peak Identification
- •References
- •19.1 What Is a k-ratio?
- •19.3 Sets of k-ratios
- •19.5 The Analytical Total
- •19.6 Normalization
- •19.7.1 Oxygen by Assumed Stoichiometry
- •19.7.3 Element by Difference
- •19.8 Ways of Reporting Composition
- •19.8.1 Mass Fraction
- •19.8.2 Atomic Fraction
- •19.8.3 Stoichiometry
- •19.8.4 Oxide Fractions
- •Example Calculations
- •19.9 The Accuracy of Quantitative Electron-Excited X-ray Microanalysis
- •19.9.1 Standards-Based k-ratio Protocol
- •19.9.2 “Standardless Analysis”
- •19.10 Appendix
- •19.10.1 The Need for Matrix Corrections To Achieve Quantitative Analysis
- •19.10.2 The Physical Origin of Matrix Effects
- •19.10.3 ZAF Factors in Microanalysis
- •X-ray Generation With Depth, φ(ρz)
- •X-ray Absorption Effect, A
- •X-ray Fluorescence, F
- •References
- •20.2 Instrumentation Requirements
- •20.2.1 Choosing the EDS Parameters
- •EDS Spectrum Channel Energy Width and Spectrum Energy Span
- •EDS Time Constant (Resolution and Throughput)
- •EDS Calibration
- •EDS Solid Angle
- •20.2.2 Choosing the Beam Energy, E0
- •20.2.3 Measuring the Beam Current
- •20.2.4 Choosing the Beam Current
- •Optimizing Analysis Strategy
- •20.3.4 Ba-Ti Interference in BaTiSi3O9
- •20.4 The Need for an Iterative Qualitative and Quantitative Analysis Strategy
- •20.4.2 Analysis of a Stainless Steel
- •20.5 Is the Specimen Homogeneous?
- •20.6 Beam-Sensitive Specimens
- •20.6.1 Alkali Element Migration
- •20.6.2 Materials Subject to Mass Loss During Electron Bombardment—the Marshall-Hall Method
- •Thin Section Analysis
- •Bulk Biological and Organic Specimens
- •References
- •21: Trace Analysis by SEM/EDS
- •21.1 Limits of Detection for SEM/EDS Microanalysis
- •21.2.1 Estimating CDL from a Trace or Minor Constituent from Measuring a Known Standard
- •21.2.2 Estimating CDL After Determination of a Minor or Trace Constituent with Severe Peak Interference from a Major Constituent
- •21.3 Measurements of Trace Constituents by Electron-Excited Energy Dispersive X-ray Spectrometry
- •The Inevitable Physics of Remote Excitation Within the Specimen: Secondary Fluorescence Beyond the Electron Interaction Volume
- •Simulation of Long-Range Secondary X-ray Fluorescence
- •NIST DTSA II Simulation: Vertical Interface Between Two Regions of Different Composition in a Flat Bulk Target
- •NIST DTSA II Simulation: Cubic Particle Embedded in a Bulk Matrix
- •21.5 Summary
- •References
- •22.1.2 Low Beam Energy Analysis Range
- •22.2 Advantage of Low Beam Energy X-Ray Microanalysis
- •22.2.1 Improved Spatial Resolution
- •22.3 Challenges and Limitations of Low Beam Energy X-Ray Microanalysis
- •22.3.1 Reduced Access to Elements
- •22.3.3 At Low Beam Energy, Almost Everything Is Found To Be Layered
- •Analysis of Surface Contamination
- •References
- •23: Analysis of Specimens with Special Geometry: Irregular Bulk Objects and Particles
- •23.2.1 No Chemical Etching
- •23.3 Consequences of Attempting Analysis of Bulk Materials With Rough Surfaces
- •23.4.1 The Raw Analytical Total
- •23.4.2 The Shape of the EDS Spectrum
- •23.5 Best Practices for Analysis of Rough Bulk Samples
- •23.6 Particle Analysis
- •Particle Sample Preparation: Bulk Substrate
- •The Importance of Beam Placement
- •Overscanning
- •“Particle Mass Effect”
- •“Particle Absorption Effect”
- •The Analytical Total Reveals the Impact of Particle Effects
- •Does Overscanning Help?
- •23.6.6 Peak-to-Background (P/B) Method
- •Specimen Geometry Severely Affects the k-ratio, but Not the P/B
- •Using the P/B Correspondence
- •23.7 Summary
- •References
- •24: Compositional Mapping
- •24.2 X-Ray Spectrum Imaging
- •24.2.1 Utilizing XSI Datacubes
- •24.2.2 Derived Spectra
- •SUM Spectrum
- •MAXIMUM PIXEL Spectrum
- •24.3 Quantitative Compositional Mapping
- •24.4 Strategy for XSI Elemental Mapping Data Collection
- •24.4.1 Choosing the EDS Dead-Time
- •24.4.2 Choosing the Pixel Density
- •24.4.3 Choosing the Pixel Dwell Time
- •“Flash Mapping”
- •High Count Mapping
- •References
- •25.1 Gas Scattering Effects in the VPSEM
- •25.1.1 Why Doesn’t the EDS Collimator Exclude the Remote Skirt X-Rays?
- •25.2 What Can Be Done To Minimize gas Scattering in VPSEM?
- •25.2.2 Favorable Sample Characteristics
- •Particle Analysis
- •25.2.3 Unfavorable Sample Characteristics
- •References
- •26.1 Instrumentation
- •26.1.2 EDS Detector
- •26.1.3 Probe Current Measurement Device
- •Direct Measurement: Using a Faraday Cup and Picoammeter
- •A Faraday Cup
- •Electrically Isolated Stage
- •Indirect Measurement: Using a Calibration Spectrum
- •26.1.4 Conductive Coating
- •26.2 Sample Preparation
- •26.2.1 Standard Materials
- •26.2.2 Peak Reference Materials
- •26.3 Initial Set-Up
- •26.3.1 Calibrating the EDS Detector
- •Selecting a Pulse Process Time Constant
- •Energy Calibration
- •Quality Control
- •Sample Orientation
- •Detector Position
- •Probe Current
- •26.4 Collecting Data
- •26.4.1 Exploratory Spectrum
- •26.4.2 Experiment Optimization
- •26.4.3 Selecting Standards
- •26.4.4 Reference Spectra
- •26.4.5 Collecting Standards
- •26.4.6 Collecting Peak-Fitting References
- •26.5 Data Analysis
- •26.5.2 Quantification
- •26.6 Quality Check
- •Reference
- •27.2 Case Study: Aluminum Wire Failures in Residential Wiring
- •References
- •28: Cathodoluminescence
- •28.1 Origin
- •28.2 Measuring Cathodoluminescence
- •28.3 Applications of CL
- •28.3.1 Geology
- •Carbonado Diamond
- •Ancient Impact Zircons
- •28.3.2 Materials Science
- •Semiconductors
- •Lead-Acid Battery Plate Reactions
- •28.3.3 Organic Compounds
- •References
- •29.1.1 Single Crystals
- •29.1.2 Polycrystalline Materials
- •29.1.3 Conditions for Detecting Electron Channeling Contrast
- •Specimen Preparation
- •Instrument Conditions
- •29.2.1 Origin of EBSD Patterns
- •29.2.2 Cameras for EBSD Pattern Detection
- •29.2.3 EBSD Spatial Resolution
- •29.2.5 Steps in Typical EBSD Measurements
- •Sample Preparation for EBSD
- •Align Sample in the SEM
- •Check for EBSD Patterns
- •Adjust SEM and Select EBSD Map Parameters
- •Run the Automated Map
- •29.2.6 Display of the Acquired Data
- •29.2.7 Other Map Components
- •29.2.10 Application Example
- •Application of EBSD To Understand Meteorite Formation
- •29.2.11 Summary
- •Specimen Considerations
- •EBSD Detector
- •Selection of Candidate Crystallographic Phases
- •Microscope Operating Conditions and Pattern Optimization
- •Selection of EBSD Acquisition Parameters
- •Collect the Orientation Map
- •References
- •30.1 Introduction
- •30.2 Ion–Solid Interactions
- •30.3 Focused Ion Beam Systems
- •30.5 Preparation of Samples for SEM
- •30.5.1 Cross-Section Preparation
- •30.5.2 FIB Sample Preparation for 3D Techniques and Imaging
- •30.6 Summary
- •References
- •31: Ion Beam Microscopy
- •31.1 What Is So Useful About Ions?
- •31.2 Generating Ion Beams
- •31.3 Signal Generation in the HIM
- •31.5 Patterning with Ion Beams
- •31.7 Chemical Microanalysis with Ion Beams
- •References
- •Appendix
- •A Database of Electron–Solid Interactions
- •A Database of Electron–Solid Interactions
- •Introduction
- •Backscattered Electrons
- •Secondary Yields
- •Stopping Powers
- •X-ray Ionization Cross Sections
- •Conclusions
- •References
- •Index
- •Reference List
- •Index
\466 Chapter 26 · Energy Dispersive X-Ray Microanalysis Checklist
Sample Orientation
Sample orientation is also a critical parameter to hold constant.
26 \1.\ The ideal sample orientation has the sample perpendicular to the electron column’s optical axis. The electrons strike the sample normal to the surface and their behavior in the sample is best understood.
\2.\ Tilts of a few degrees from the ideal perpendicular orientation can significantly degrade the accuracy of quantitative measurements for highly absorbed X-rays, such as low energy photons below 1 keV.
\3.\ The best way to ensure that the samples are oriented correctly is by checking the orientation of the stage using a spirit level and then ensuring that the sample’s surface is parallel to the stage datum. Check both orientations as a stage may be perpendicular to the optic axis in one direction (x or y) and tilted on the other (y or x).
\4.\ Sometimes it is not possible to use a level to ensure orientation, in these cases you may be able to use a flat portion of the sample and the image focus to ensure that the sample maintains focus as the stage moves. A 1° tilt corresponds to a change of working distance of 17 μm over a travel of 1 mm.
Detector Position
Maintaining the position of the detector relative to the sample is critical. The sample position aspect of this has been discussed above in terms of setting the proper working distance. On some instruments, it is also possible to position the X-ray detector along a slide mount with a screw drive (manual or motor driven) that moves the detector along its central axis out of the chamber and away from the sample.
\1.\ Usually, the optimal location for the detector is as close to the sample as possible without obstruction or collision.
\2.\ The detector snout should not touch anything inside the chamber. The snout should be electrically isolated from the chamber.
\3.\ The position of the detector should be maintained by setting a stop that ensures that the detector is returned to precisely the same position each time it is removed and returned.
\4.\ The solid angle and therefore also the throughput is a function of the distance of the detector to the sample squared. Thus small variations in this distance can contribute to large differences in measured X-ray intensities. A 1 % error in distance leads to a 2 % error in intensity.
\5.\ On a few instruments, the take-off angle can be varied. A single take-off angle should be selected and maintained. All else remaining the same, higher take-off angles are better than lower ones.
Probe Current
\1.\ It is not necessary to maintain exactly the same probe current throughout the entire measurement process but it is beneficial to try to maintain the probe current to a
narrow range because this minimizes errors resulting from non-linearities in the picoammeter.
\2.\ Typically, the probe current is selected to maximize the X-ray throughput on a selected material (e.g., Cu), while simultaneously maintaining a low rate of coincidence events (pulse pile-up).
\3.\ Coincidence events occur at all throughputs but become much more common at higher throughputs (scaling roughly as the square of the throughput). The acceptable coincidence rate is composition dependent. Lower probe currents and lower coincidence rates are required for trace element analysis and when a coincidence event occurs at the same energy as a minor elemental peak.
\4.\ Older Si(Li) detectors with lower throughputs typically had less of an issue with coincidence events and maintaining a dead time of 30 % was close to optimal for all vendors and most samples.
\5.\ Silicon drift detectors are capable of higher throughput but are also more susceptible to coincidence events so an acceptable coincidence rate, rather than a specific dead time, should be used as a metric to select the probe current. Note that coincidence depends strongly on how many high-count-rate peaks are present in the spectrum, so the degree of coincidence will vary with composition.
\6.\ A good starting point is to observe the coincidence events that occur with alumina (Al2O3). Adjust the probe current to maintain the amplitude of the largest coincidence peak on this challenging sample as less than 1 % of the amplitude of the parent peak.
26.4\ Collecting Data
26.4.1\ Exploratory Spectrum
1.\ Before proceeding to collect final data on a sample, it is generally a good idea to collect an exploratory spectrum. This exploratory spectrum should be collected for sufficiently long to ensure that all the elements (major, minor, and trace) present in specimen can be identified. This exploratory spectrum can also be used to determine how long an acquisition will be necessary to get the precision you desire for each element in the spectrum.
2.\ Subject the exploratory spectrum to qualitative analysis using the vendor-supplied automatic peak identification tool but always follow with manual inspection of the suggested elemental identifications to determine validity. The elements identified will determine the standards that will be necessary for the analysis.
3.\ If you suspect that an element may also be present but is obscured by another element, a standard should be collected for that element too.
4.\ It may be beneficial to perform a standardless analysis on the exploratory spectrum to get a rough idea of the composition of the unknown (Be sure that the manually confirmed element list, not the raw automatic peak identification list, is used for the standardless analysis.)
26.4 · Collecting Data
26.4.2\ Experiment Optimization
Determining the peak fitting reference requirements and the optimal acquisition times can be a challenge. DTSA-II provides a tool to help. The user provides an estimate of the composition of the unknown (crude estimates are fine), the standards you are going to use and the desired measurement precision and the tool will tell you when references are required and suggest approximately how long to acquire each standard, reference and unknown spectrum.
26.4.3\ Selecting Standards
1.\ Select a standard for each element that you believe is present in the unknown.
2.\ In certain problem domains, you may be able to omit a standard if you calculate oxygen by assumed stoichiometry or assume an element by difference from an analytical total of one.
3.\ It’s generally best to assume that you will measure every element and collect a standard for each. You can always change your mind later.
4.\ Initially, it is probably best to select a simple standard (one for which no peak shape references are required)
26.4.4\ Reference Spectra
References serve two purposes:
\1.\ To resolve interferences in multi-element standards 55Example: In BaF2, the Ba M lines interfere with the F K
lines. To use BaF2 as a standard for Ba, two references (e.g., BaCl2 for Ba and CaF2 for F) are required to provide clear, interference-free views of the Ba M-family peaks and the F K-family peaks in the range of energies in which the Ba M lines interfere with the F K lines.
\2.\ To strip elements which are known to contribute to the unknown spectrum but are not really present in the material
55Example: A reference to strip a thin conductive coating of Au, Pt, or C.
26.4.5\ Collecting Standards
1.\ Since standards will typically contribute to many measurements, it is generally a good idea to spend extra time to ensure that standards are of high quality.
2.\ The total acquisition time necessary depends upon the measurement goals and can be determined by examining the intensity in an element’s characteristic peaks. In particular, you should examine the characteristic peaks that will be used to perform the quantification. The background corrected peak integral should contain at least 10,000 counts for approximately 1 % precision or 160,000 counts for 0.25 % precision.
|
|
|
467 |
|
|
26 |
|
|
|
|
|
|
|
3.\ |
It is generally better to collect multiple shorter acquisi- |
|
||||
|
tion spectra from multiple points on the standard and |
|
||||
|
build a single high-quality standard spectrum from the |
|
||||
|
best of these. Collecting multiple spectra allows you to |
|
||||
|
discern problems with individual spectra that may oth- |
|
||||
|
erwise go unnoticed. |
|
||||
4.\ |
Collect N where N> 2 spectra from various different |
|
||||
|
points on the standard. |
|
||||
|
55Measure and record the probe current before collect- |
|
||||
|
ing each spectrum and after the last. |
|
||||
|
55Note any significant changes in probe current where |
|
||||
|
“significant” is determined by the desired measure- |
|
||||
|
ment precision. |
|
||||
5.\ Compare the N spectra but plotting them simultane- |
|
|||||
|
ously using the same vertical scale for all. Examine care- |
|
||||
|
fully the intensity in the characteristic peak of choice. |
|
||||
|
Discard any spectra which differ systematically by more |
|
||||
|
than counting statistics. Sum the remaining spectra |
|
||||
|
together to form a single spectrum. |
|
||||
6.\ |
Ensure the following properties are assigned to the stan- |
|
||||
|
dard spectrum. |
|
||||
|
(i)\ |
Beam energy |
|
|||
|
(ii)\ |
Probe current |
|
|||
|
(iii)\ Live-time |
|
||||
|
(iv)\ Composition of the standard |
|
||||
7.\ |
Save the standard to disk. |
|
||||
8.\ |
Repeat for each required standard. |
|
26.4.6\ Collecting Peak-Fitting References
References serve as examples of an element’s characteristic peak shapes. The factors that make for a good reference are different from those that make a good standard.
\1.\ A good material for a reference need not be as carefully mounted and prepared as a standard or unknown.
\2.\ Particles or rougher surfaces can serve as adequate reference materials.
\3.\ You don’t need to know the probe current or live-time. \4.\ While it is generally a good idea to collect the reference at the same beam energy (particularly for lower over-
voltages on the L and M lines), it is not always necessary. \5.\ References should be high count spectra but are less susceptible to count statistics than the standards. In general,
a reference should have significantly more than 10,000 counts in the element’s useful characteristic peak to provide an adequate perspective of the peak shape.
\6.\ Simple elemental standards can always be reused as references.
\7.\ Save the references to disk.
26.4.7\ Collecting Spectra
From the Unknown
1.\ Examine the exploratory spectrum to determine how long an acquisition time to use for the unknown